Overview

Using the RAE detection tubes, gas or vapour concentrations can be determined by drawing an air sample through a tube containing a reagent, causing a visual colour change. The concentration is read from the length of the colour stain shown by the reagent. The advantages of detection tubes over other analytical methods are simplicity of use, rapid response, low cost, and very low maintenance. Because each batch of tubes is pre-calibrated, the user does not need any calibration equipment.

Reading the Tubes

The concentration of the compound being measured is read directly from the scale printed on the tube. The reading is taken as the furthest distance along the tube that the colour change becomes visible. If the leading edge is diagonal instead of perpendicular to the axis of the tube, use the average of the maximum and minimum values.

Drawing a sample through the tubes

RAE Systems sample tubes require a pump to draw a sample. One of the following pumps is required:

Features & Benefits
  • Cheap and easy to use.
  • Allows accurate readings to be taken in the field.
Available Tubes

Type Part Number Standard Range

Acetone (C3H6O)

10-111-40

0.1 - 2%

Amines (RNH2)

10-132-10

0.5 - 10 ppmv

Ammonia (NH3)

10-100-05

1 - 30 ppmv

 

10-100-10

5 - 100 ppmv

 

10-100-12

10 - 260 ppmv

 

10-100-15

25 - 500 ppmv

 

10-100-40

1 - 15%

Benzene (C6H6)

10-101-01*

0.5 - 10 ppmv selective

 

10-101-10*

5 - 40 ppmv selective

 

10-101-20

5 - 100 ppmv

Butane (C4H10)

10-137-30

25 - 1400 ppmv

Carbon Dioxide (CO2)

10-104-30

300 - 5000 ppmv

 

10-104-40

0.05 - 1%

 

10-104-45

0.25 - 3%

 

10-104-50

1 - 20%

 

10-104-60

5 - 40%

Carbon Monoxide (CO)

10-102-18

5 - 100 ppmv selective

 

10-102-20

5 - 100 ppmv

 

10-102-30

20 - 500 ppmv

 

10-102-45

0.2 - 4%

Chlorine (Cl2)

10-106-10

0.5 - 8 ppmv

 

10-106-20

5 - 100 ppmv

Chlorine Dioxide (ClO2)

10-130-10

0.25 - 15 ppmv

Diesel Fuel & Jet Fuel

10-143-10

0.5 - 25 ppmv

Ethanol (C2H6O)

10-141-30

100 - 2000 ppmv

Formaldehyde (CH2O)

10-121-05

0.1 - 5 ppmv

Gasoline (CnHm)

10-138-30

30 - 1000 ppmv

Hydrocarbons (HC)

10-110-30

50 - 1000 ppmv

Hydrogen Chloride (HCl)

10-108-09

1 - 20 ppmv

 

10-108-10*

1 - 20 ppmv w/desiccant

 

10-108-22

20 - 500 ppmv w/desiccant

Hydrogen Cyanide (HCN)

10-126-10

2.5 - 60 ppmv

Hydrogen Fluoride (HF)

10-105-10

0.5 - 20 ppmv

Hydrogen Sulfide (H2S)

10-103-04

0.2 - 3 ppmv

 

10-103-05*

0.2 - 3 ppmv w/desiccant

 

10-103-06

1 - 7 ppmv

 

10-103-10

2.5 - 60 ppmv

 

10-103-15

10 - 120 ppmv

 

10-103-18

25 - 250 ppmv

 

10-103-20

50 - 800 ppmv

 

10-103-30

100 - 2000 ppmv

 

10-103-40

0.1 - 2%

 

10-103-50

2 - 40%

MEK - Methyl Ethyl Ketone (C4H8O)

10-113-20

0.02 - 0.6%

Mercaptans (RSH)

10-129-20

5 - 120 ppmv

Methyl Bromide (CH3Br)

10-131-10

1 - 18 ppmv

Nitrogen Dioxide (NO2)

10-117-10

0.5 - 30 ppmv

Nitrogen Oxides (NOx)

10-109-20*

1 - 50 ppmv

Ozone (O3)

10-133-03

0.05 - 0.6 ppmv

Phenol (C6H6O)

10-139-05

1 - 25 ppmv

Phosphine (PH3)

10-116-10

5 - 50 ppmv

 

10-116-20

25 - 500 ppmv

 

10-116-25

50 - 1000 ppmv

Sulfur Dioxide (SO2)

10-107-15

2 - 30 ppmv

 

10-107-20

5 - 100 ppmv

 

10-107-25

100 - 1800 ppmv

 

10-107-30

200 - 4000 ppmv

 

10-107-40

0.2 - 5%

Toluene (C7H8)

10-114-20

10 - 300 ppmv

Trichloroethylene (C2HCl3)

10-119-20*

5 - 100 ppmv

Vinyl Chloride (C2H3Cl)

10-128-10*

1 - 20 ppmv

Water Vapor (H2O)

10-120-10

2 - 10 lbs/MMCF

 

10-120-20

6 - 40 lbs/MMCF

 

10-120-30

0.05 - 1.0 mg/L

 

10-120-40

1 - 18 mg/L

Xylene (C8H10)

10-112-20

10 - 200 ppmv

* An asterisk (*) in the chart above indicates boxes containing 5 colorimetric tubes and 5 pre-tubes, for a total of 5 measurements. Standard boxes without the asterisk have 10 tubes.